Module PACK testing equipment
HB-EOL100V/200V/300V/1000V
PACK/Module EOL Comprehensive Test System
Electric vehicles, buses, residential energy storage, and container energy storage — for battery module/PACK end-of-line testing and quality control.
Applications
Electric Vehicles
Buses
Home Energy Storage
Container Energy Storage
Battery Module/PACK End-of-Line Testing & QC
TEST CAPABILITIES
AC Internal Resistance (ACIR)
Pack Insulation Test
Pack AC Withstand Voltage Test
Pack DC Withstand Voltage Test
CAN Termination Resistance Test
BMS Communication Test
Relay Function Verification
PRODUCT FEATURES
01
Ultra-High Current Output
Up to ±1000A per channel for high-rate testing of high-power battery packs.
02
High-Efficiency Energy Feedback
Proprietary DSP-based energy feedback feeds discharge energy back to the grid, cutting test energy use and heat output.
03
Multiple Protections
Over-temperature, over/under-voltage, reverse connection, power-loss resume and overcurrent protection for safe testing.
04
High Accuracy & Stability
Precision ADC and alloy sensing components ensure stable high-current testing.
05
Modular Design
Drawer-style channel modules for easy upgrade and maintenance.
06
Smart PC Software
Parameter setup, data monitoring, power-loss resume; flexible step combinations, visual analysis and Excel export.
07
Contactless High-Current Switching
Innovative contactless electronic switching delivers spark-free control, avoiding circuit surge and flashover risks.
TECHNICAL DATA
| Model | EOL‑100V | EOL‑200V | EOL‑300V | EOL‑1000V |
|---|---|---|---|---|
| Battery Voltage Range | ±100V | ±200V | ±300V | ±1000V |
| ACIR Range | 1‑3000mΩ | |||
| DCIR Range | 1‑3000mΩ | |||
| AC Withstand Output Capacity | 200VA | |||
| AC Withstand Range | 50V ~ 5000V | |||
| AC Withstand Accuracy | ±(2%rdg.+5dgt.) | |||
| AC Withstand Resolution | 1V | |||
| AC Current Limits | 0.10A ~ 40.00mA | |||
| DC Withstand Output Capacity | 60VA (6000V/10mA) | |||
| DC Withstand Range | 50V ~ 6000V | |||
| DC Withstand Accuracy | ±(3%rdg.+10dgt.) | |||
| DC Current Limits | 0mA ~ 9.999mA | |||
| Insulation Resistance Output Voltage Range | 25V ~ 3000V | |||
| Insulation Resistance Accuracy | 3%rdg.+3dt ~ 15%rdg.+30dgt. | |||
| Insulation Resistance Upper Limit | 0 ~ 50000MΩ | |||
| Insulation Resistance Lower Limit | 0.3MΩ ~ 99.9MΩ / 100MΩ‑50000MΩ | |||
| Time Range | 1.0s ~ 999.9s | |||
Need product selection or a customized testing solution?