Module PACK testing equipment
HB-DC-100V30C100D
Battery Overall Performance Testing System
Electric bicycles, electric motorcycles, robots, AGV batteries, energy storage for solar-powered base stations, automotive starting batteries, solar energy storage, wind energy storage, and commercial & industrial (C&I) energy storage, etc.
Applications
E-bikes & E-motorcycles
Robotics & AGV Batteries
Solar Storage, Base-Station Backup, Car Starter Batteries
Wind Storage, Commercial & Industrial Energy Storage
TEST CAPABILITIES
AC Internal Resistance (ACIR)
DC Internal Resistance (DCIR)
Charge Activation (Wake-Up Charging)
Charge Voltage/Current/ΔV/Overcurrent Protection
Discharge Voltage/Current/ΔV/Overcurrent Protection
Short-Circuit Protection Test
Foot-Switch Start
Scan-to-Start (Barcode Logging)
PRODUCT FEATURES
01
Fully Modular Design
Modular architecture for high reliability and easy maintenance/upgrades.
02
Main Controller
High-performance ARM controller for smooth, stable operation.
03
Smart PC Software
Clean UI with editable test step sequences and adjustable parameters.
04
Scan Support
Supports 1D/2D barcodes, scan-start and foot-switch start.
05
Safety Protection
Charge/discharge reverse connection protection with warning.
06
Higher Accuracy
24-bit ADC for higher voltage/current accuracy than industry standard.
07
High Stability
4-wire voltage/current sampling for high accuracy and long-term stability.
08
Easy Data Storage
Auto-saves test data to a powerful database for quality traceability.
TECHNICAL DATA
| Model | DC‑100V30C100D | DC‑100V50C200D | DC‑100V50C300D | DC‑200V100C200D | DC‑200V150C300D |
|---|---|---|---|---|---|
| Test Voltage | 100V | 200V | |||
| Charge Current | 30A | 50A | 50A | 100A | 150A |
| Discharge Current | 100A | 200A | 300A | 200A | 300A |
| Max Charge Overcurrent | 30A | 50A | 50A | 100A | 150A |
| Charge Overcurrent Accuracy | ±2A | ||||
| Max Discharge Overcurrent | 200A | 300A | 200A | 300A | 60A |
| Charge Current Accuracy | ±0.5% of F.S ±0.5% of F.D | ||||
| Discharge Current Accuracy | ±0.5% of F.S ±0.5% of F.D | ||||
| Discharge Overcurrent Accuracy | ±2A | ||||
| Voltage Accuracy | ±0.05% of F.S ±0.05% of F.D | ||||
| Voltage Resolution | 1mV | ||||
| Current Resolution | 1mA | ||||
| ACIR Range | 1‑3000mΩ | ||||
| ACIR Accuracy | 1mΩ | ||||
| DCIR Range | 1‑3000mΩ | ||||
| DCIR Accuracy | 1mΩ | ||||
| Differential Voltage (ΔV) Test Accuracy | 1mV | ||||
| Short-Circuit Protection Time | 1‑10000us | ||||
| Power-Loss Protection | Auto-disconnects the battery from the device on unexpected AC power loss | ||||
| Emergency Stop | Pressing e-stop disconnects the battery and cuts off device load power | ||||
| Data Storage | Data saved as CSV files | ||||
| Voltage/Current Sensing | 4-wire connection | ||||
| Input Voltage | AC220V 50HZ±10% | AC380V 50HZ±10% | |||
Need product selection or a customized testing solution?