Portable testing equipment
HBMV-120V-D60A-EXT
Module charging and discharging capacity tester(External Charger Version)
The HB-120V-C25A-EXT Module Charging and Discharging Capacity Tester is used for charge/discharge and capacity testing of lithium battery packs, battery packs, and lead-acid batteries. It has no built-in charging module; an external charger serves as the charging source. The tester performs charge voltage/current setting, process control, data acquisition, and protection. The charging limits are governed by the maximum voltage and current of the external charger. The tester suits applications where a charger is already available or a higher charging current is required, and it carries a lower purchase cost.
Applications
Test performance across charge, discharge and SOC ranges.
Charge/discharge testing & QC standards for battery and PACK makers.
Battery recycling & repair: used battery testing and fault diagnosis.
Test prototypes of various specs (capacity, size) to validate design parameters.
TEST CAPABILITIES
CC/CV/CCCV Module Charge & Discharge
DC Internal Resistance Test
CV/Time/Capacity-Limited Charge & Discharge
Cycle Aging Test
PRODUCT FEATURES
01
Medium/High Voltage Coverage
Up to 120V with 25A charge / 60A discharge, covering most module and PACK test needs.
02
Precise Control
CC, CV and CCCV charge/discharge with no current surge on switching.
03
Multiple Protections
Overvoltage, overcurrent, over-temperature and reverse connection protection for safe testing.
04
Smart + Pro Dual Mode
Smart mode for quick tests, or professional parameters for cell charge, discharge and capacity grading.
05
Portable Design
7" color touchscreen UI, clean interface, easy to operate.
06
External Charger
You can reuse the charging-module capability of an existing charger. As long as the limits of that charging module are not exceeded, you can set the charging voltage and current freely. This saves purchase cost.
TECHNICAL DATA
Parameter | Value |
Model | HBMV-120V-D60A-EXT |
AC Power Supply | Single-phase 3-wire AC110-264V @50Hz |
Charge/Discharge Voltage | Discharge voltage 10–120 V, adjustable; charging voltage upper limit limited by the external charger |
Voltage Accuracy | ±(0.05%+2)FS |
Charge/Discharge Current | Maximum discharge current 60 A; charging current upper limit limited by the external charger. |
Current Accuracy | ±0.05%FS |
Ambient Temperature | -10℃~45℃ |
Relative Humidity | ≤70% |
Temperature Sensing | Built-in (-39℃~90℃) |
Display | 7" color touchscreen |
Test Leads | Dual isolated alligator clips (customizable) |
Data Storage | Records current run data |
Communication Interface | TTL serial |
Need product selection or a customized testing solution?